Phyn Plus can be installed indoors or outdoors, and mounted horizontally or vertically.

Installation location requirements

  • Install Phyn Plus on the main water supply pipe, immediately after the main shutoff valve and before any branches, fixtures, or devices.

  • Phyn monitors only the plumbing downstream (after) the device.

    • Pipes, fixtures, irrigation systems, or water softeners upstream (before) the device will not be monitored

  • Do not install Phyn Plus in any location where it could:

    • Be submerged in water

    • Be exposed to direct spray from high-flow irrigation or sprinkler systems

Power and mounting requirements

  • Phyn Plus must be installed within 11 feet of a 120V electrical outlet.

  • A GFCI-protected outlet is strongly recommended.

  • For safety, the device must be mounted so the lowest edge of the enclosure is at least 12 inches above ground level.

⚠️ Safety notice: Installing the device lower than the required height may increase the risk of electric shock.